Vue de la page 0
12V BATTERY
Grommet
Firewall
OPTIONAL SLIT TUBING RECOMMENDED
(AVAILABLE AT MOST HARDWARE STORES)
Pro Control
Low Output #1
Pro Control
High Output #2
Red
Blue
Orange
Yellow
Black
Black
Illumination
White
+12v Dash
Lighting
Data Logger
Output
Wiring
Harness
Sender 1/8" NPT
Thread Size
Fuse
(See Caution Left)
+12v Connection
(See Lighting Mode)
Good Engine Ground
(Pro Control Ground)
Data Logger
Ground
INSTALLATION INSTRUCTIONS
ELITE SERIES
FULL SWEEP ELECTRIC TEMPERATURE GAUGE
2650-1408-00 Rev. A
USE TEFLON SEALING
TAPE OR SEALING
COMPOUND ON
PIPE THREADS
CAUTION!
As a safety precaution, the
+12V terminal of this product
should be fused before
connecting to the 12V ignition
switch. We recommend
using a 1 Amp, 3AG fast-
acting type cartridge fuse
(Littlefuse
®
# 312 001 or an
equivalent).
Installation
NOTE: When the ignition is off the pointer may not always rest at zero.
NOTE: Some late model vehicles use electronic sensors in their
pressure and temperature senders for engine control
functions. Before removing the original sender, we
recommend that you contact your automotive dealer to be
sure no critical functions will be disrupted.
1. Check that you have all parts required for installation,
and the engine is cool.
2. Disconnect the negative (-) battery cable.
3. Gauge mounts in a 2
5
8" hole for 2
5
8" gauges and a 2-
1
/16
"
hole for 2-
1
/16
" gauges. Use supplied brackets and
nuts to secure gauge to dash.
4. Drill 1" diameter hole where wires pass through sheet metal
(such as firewall and install rubber grommet provided.
(Grommet will require slit.)
5. Connect the white wire to dash lighting or switchable 12v light
source, the red wire to switched +12V source and the black
wire to ground.(see diagram for details)
6. Install temperature sender.
A. Water Temp: Install temperature sender.
Note: Included sender is
1
/8" NPT. For
3
/8" NPT or
1
/2"
NPT ports, use included adapter.
Power-Up
The pointer will move counter clockwise to the stop pin and then moves to the current gauge reading. This procedure is an auto-calibration
function and is performed on every power-up. While this test is being performed, the gauge may make a clicking sound. This is normal.
Peak Recall
Press and hold the PEAK button to recall the highest temperature reading since the memory was last cleared. To clear the memory, press
and hold the PEAK button, and while still holding the PEAK button, press the WARN button. The pointer will move to the stop pin to indicate
that the memory has been cleared. Release the PEAK and WARN buttons to resume normal operation. The peak recall point is retained when
power is removed from the gauge.
Full Dial Warning
This gauge features full dial warning. When a warning point is reached, the entire dial illuminates in the programmed warning color. This feature
is available for both a high and low warning set point. In addition, the warning color will flash when an over warn point is reached.
B. Trans. Temp: Hole may have to be drilled, and adapter
nut welded or brazed in pan. Be sure there is adequate
internal clearance for nut and sender.
7. Cut end of included dielectric grease packet, and squeeze grease
into connector of temperature sender prior to connecting harness.
(Important: This will protect connection from dirt and moisture.)
8. Connect red wire to switched +12V source and the black wire to
ground. (see diagram for details)
9. Reconnect negative (-) battery cable.
NOTE: Test all fittings and connections for leaks. If any leaks are
detected, determine the cause of the leak and repair.
Do not operate vehicle if any leaks are detected.
NOTE: Do not remove factory temp sender to install temp sender. If no
location found, a hose adapter can be used.
Caution: LUBRIPLATE
®
DS-ES is a non-hazardous substance.
However, it is recommended to wash hands thoroughly after use.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - INSTALLATION INSTRUCTIONS

12V BATTERY GrommetFirewallOPTIONAL SLIT TUBING RECOMMENDED(AVAILABLE AT MOST HARDWARE STORES)Pro Control Low Output #1Pro Control High Output #2RedBl

Page 2

Pro Control High Warning Set PointTo adjust the high warning set point, press and release the WARN button. The warning light will begin to flash and t

Page 3 - Pro Control Active States

Lighting Mode(Region B Color)This gauge allows the dial lighting to operate in two modes, Full On or Dimmable. Factory default is Full On.Full On: In

Page 4 - Pro Control

Pro ControlThe Pro Control feature activates a switched ground output at a user defined set point. Pro Control can be used to switch on a relay to act

Modèles reliés 5658 | 5654 | 5655 |